Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.9452212
- Product Categories
- Friendly Links
Information Name: | To supply Turner TD-3100 desktop oil-in-water analyzer |
Published: | 2013-05-17 |
Validity: | 180 |
Specifications: | |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | Turner TD-3100 desktop oil in water analyzer, measuring oil content analyzer, the UV Fluorescence Oil Content Analyzer Name: Desktop oil in water analyzer Model: TD-3100 detected objects: water, oil, petroleum, water and hydrocarbons brand: United States Turner (Turner Designs Hydrocarbon Instruments, Inc.) Turner official website: http://oilinwatermonitors.com/ one instrument: TD-3100 is a high-precision laboratory bench of Oil in Water analysis instruments for the analysis of water and hydrocarbons in the soil. The development of the instrument is designed to provide an ideal choice for the industry-standard laboratory methods. The instrument uses a solution of (n-hexane) extraction method or the use of non-extraction method to measure the sample in the solubility range. When set to direct concentration mode (the Direct Concentraion Mode), the meter will display the value of the true concentration of hydrocarbons. Just change the optical configuration, you can set up the TD-3100 is used to detect a range of hydrocarbons, including: crude oil, diesel oil, or mixed oils. By replacing the TD-3100 of the aggregate of the optical element with high sensitivity fluorescence detector capable of detecting from hydrocarbons within a millionth (ppm) to one billionth (ppb) range. Detection Principle: ultraviolet fluorescence method, the aromatic component of the petroleum in the water, the ultraviolet radiation of a specific wavelength in the ultraviolet region, after excitation emits fluorescence intensity, fluorescence intensity and the oil component is proportional to the amount of longer wavelength. TD-3100 by detecting the particular fluorescence intensity measured concentration of oil in water. Second, the range of applications: for oil: benzene, phenol, styrene, amino, electronically controlled hydraulic fluid, gasoline; diesel oil, lubricating oil, hydraulic oil, fuel oil, crude oil, gas condensate oil. Detection limit: the maximum limit: diesel extracted in distilled water, the approximate detection limit (10 ppb): Some oils can be as high as 1000 ppm. Applications: 1, cooling water, steam condensate, metalworking fluids concentration control; drinking water entrance, desalination plant, rivers, lakes; 3, industrial, electric power, hydropower wastewater; stormwater runoff; 4, oilfield produced water, refinery wastewater, the last liquid flow; desalination plant tail water discharge;, portable oil spill response. Third, the detection step: take 100 ml of the water sample, add 10 mL of n-hexane extract oscillation extraction 2 minutes, allowed to stand for 2 minutes, until the water - n-hexane extract hierarchical supernatant extract was dried cuvette in the TD- 3100 detected after 5 seconds, the instrument directly displays the concentration of the oil. (Simple step speed, instead of the infrared method of carbon tetrachloride with relative safety of n-hexane.), The instrument features: 1, advanced fluorescence techniques, more sensitive and more accurate; 2, with the relative safety of n-hexane instead of infrared method of carbon tetrachloride, and are compatible with all commonly used extraction solution; 3, stronger anti-interference ability of suspended solids and other substances other than oil, is more focused on oil; 4, the most rapid analytical procedures ( <4 min / sample), at least the steps (step 4: Sampling, extraction, take liquid detection); 5, suitable for a variety of applications rapidly changing multi-combination of optical elements; 6, the detection limits by the application determines, 10ppb to 1000ppm change; convenient CheckPoint solid calibration sample, rapid testing instrument stability without re-equipped with a standard solution. , The technical parameters: detection limit: According to different purposes, changes in the ppb to ppm Power supply: external power supply, 100-240 VAC, maximum power of 30 watts Weight: 13 lbs (5.9 kg) Operating temperature :60-95 ° F 15-36 ° C: 16 × 2 character LCD display; (3.86 "x 86"; 98cm x 2.18cm) Data Output: 100% ASCII format through a 9-hole serial cable at 9600 baud output available than cuvette: containing 10 × 10 × 45 square cuvette adapter. Customers can also choose can accommodate up to 25 × 150 mm test tube of 25 mm adapter. Can accommodate 13 x 100 mm test tube adapter is available for selection. Filter tube: accommodate 8 to 25 mm (1 inch) round filters (four excitation filters and four emission filters Software: menu-driven microprocessor control software detectors: factory-installed photomultiplier tube lamps: according to the actual application materials: Underwriters Laboratories (UL) certification polyurethane read out the back and bottom of the sheet metal: the direct concentration (ppb, ppm, mg / L) or raw fluorescence calibration: multi-point calibration for direct concentration measurement or original single-point the fluorescence calibration blank: Read and delete the blank separated from the sample mean: to improve the accuracy of the sample readings to average (7 seconds delay; 12 seconds for the signal average; 5 seconds screen display reading) warranty: 1 year warranty Certification: CE, UL and C-UL certification, TD-3100 can meet the standard: 1, 1: water quality performance standards of urban sewage treatment plant emission standard (GB18918-2002) and basic control: petroleum maximum allowable emission concentration (days average): a standard: A standard 1mg / L, B standard 3 mg / L; secondary standard: 5 mg / L; three standards: 15 mg / L water quality performance standards: Surface Water Environmental Quality Standard GB 3838-2002 "basic control project: the petroleum standard limits: (4.1 Table 1 surface water environmental quality standards in the standard limits ) class I, class II, class III standard: ≤ 0.05 mg / L; class IV standard: 0.5 mg / L; class VI standards: 1.0 mg / L, water quality testing standards: marine monitoring GB 17378.4-2007 " Basic controls: (14) oil (equivalent) detection method: 14.1 extraction fluorescence spectrophotometry, 14.3 gravimetric method, 14.4 UV spectrophotometry. 7, About Turner Turner (Turner Designs Hydrocarbon Instruments, Inc..) Instruments, Inc. is a leading global hydrocarbon analyzer, oil-in-water monitor R & D, production companies, has a state-of-the-art patented technology and experience in the field of oil in water analyzer developed including the oil water quality online detector, laboratory Desktop measuring oil content analyzer and portable handheld concentration of oil in water analyzer, provides a complete set of oil water quality analysis solutions. U.S. Turner oil in water analyzer is widely used in petroleum, petrochemical, offshore drilling platforms, industrial enterprises and environmental monitoring and other departments, to help customers with outstanding product performance to enhance oil Grade detection technology. U.S. Turner comprehensive product line, covering a variety of detection applications for various user requirements: TD-500D: portable dual-channel water, on-site / field emergency ; TD-3100: desktop, laboratory use; TD-1000C: oil-in-water monitoring; TD-4100C: online oil in water monitoring (the closed flow pool); TD-4100: Online monitoring of oil-in-water (open flow pool); TD-4100XDC: line oil in water monitoring (closed flow pool, explosion-proof version); TD-4100XD: line oil in water monitor (open-flow pool, explosion-proof version); TD-4100XD & XDC (the EO9 version ): software control, dual-channel switching For more product information, please visit the official website of the United States Turner at: http://www.oilinwatermonitors.com. Contact: Guangzhou Chun Tak Instrument Co., Ltd. Contact: Mr. Chen 18122351750 phone 020 -83270627, 62158611 Fax 020 -62158631 E-mail: 18122351750@189.cn business QQ: 2,804,272,353 Address: Yuexiu District, Guangzhou City, the liberation of South Road, No. 123, Jinhui Building, Room 801 |
Admin>>>
You are the 12466 visitor
Copyright © GuangDong ICP No. 10089450, Guangzhou Chun Tak Instrument Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 12466 visitor
Copyright © GuangDong ICP No. 10089450, Guangzhou Chun Tak Instrument Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility